PUMP UNIT , CENTRIFUGAL

Definition:

AN ASSEMBLED UNIT CONSISTING OF A COMMONLY MOUNTED CENTRIFUGAL PUMP(S), PRIME MOVER(S), AND THE NECESSARY COMPONENTS TO PROVIDE FOR A COMPLETE OPERATION.

CAGE Information

Code Company
59975 AMTROL INC

Federal Supply Class

Title

POWER AND HAND PUMPS

Inclusions:

Exclusions:

EXCLUDES LABORATORY JET PUMPS (FSG 65 AND 66).

Characteristics (Decoded)

MRC Requirements Statement Clear Text Reply
AMPS CURRENT RATING IN AMPS 1.6
FREQ FREQUENCY IN HERTZ 60.0
AHZF CENTRIFUGAL PUMP IMPELLER QUANTITY 1
AHZS OPERATION RELATIONSHIP DESIGN SIMULTANEOUS
ELEC VOLTAGE IN VOLTS 115.0
AHZV SUBMERSIBILITY (NON-CORE) NONSUBMERSIBLE
ADZC ENVIRONMENTAL PROTECTION DRIPPROOF
AKNA INCLOSURE TYPE FULLY INCLOSED
AAXS PRIME MOVER COOLING MEDIUM AIR
AAYU INTAKE CONNECTION TYPE THREADED INTERNAL
AHYZ OPERATING SPEED AT RATED CAPACITY 1750.0 REVOLUTIONS PER MINUTE
AENC PUMP QUANTITY 1
ASWT INTAKE CONNECTION THREAD SIZE AND SERIES/TYPE DESIGNATOR 1.250-11-1/2 NPT
AKDJ PRIME MOVER TYPE ELECTRIC MOTOR
AHZG CENTRIFUGAL PUMP IMPELLER SUCTION TYPE SINGLE
AAYW DISCHARGE CONNECTION TYPE THREADED INTERNAL
AHZA PUMPING ELEMENT OPERATING POSITION HORIZONTAL
CSYL PRIME MOVER POWER RATING 0.250 HORSEPOWER
AHYW DISCHARGE PRESSURE 175.0 POUNDS PER SQUARE INCH GAGE
FEAT SPECIAL FEATURES SUCTION AND DISCHARGE CAGE PORTS LOCATED FOR EASE ACCESS
AHYX TOTAL HEAD 12.000 FEET
AAYT INTAKE CONNECTION QUANTITY 1
AENK COOLING METHOD AIR TO AIR COOLED
AAXH PRIME MOVER QUANTITY 1
AAYD STAGE QUANTITY 1
AAXX MOUNTING TYPE FRAME
ACKL MEDIA FOR WHICH DESIGNED WATER, FRESH
AAYV DISCHARGE CONNECTION QUANTITY 1
ASAZ DISCHARGE CONNECTION THREAD SIZE AND SERIES/TYPE DESIGNATOR 1.250-11-1/2 NPT
AHYV MAXIMUM DISCHARGE FLOW RATE 52.0 GALLONS PER MINUTE
AHZE CENTRIFUGAL PUMP DESIGN AXIAL FLOW
ACDC CURRENT TYPE AC
FAAZ PHASE SINGLE